Skip to Content

Schneider THERMAL OVERLOAD RELAY

https://www.hsedubai.com/web/image/product.template/108800/image_1920?unique=29e3b48

Electrical / Breaker / MCCB

999.00 AED 999.0 AED 999.00 AED

Not Available For Sale

    This combination does not exist.

    Terms and Conditions
    30-day money-back guarantee
    Shipping: usually 2-3 Business Days, once order is placed, actual lead time will be confirmed.


    It is a MH Vigi add-on module for 3 poles Compact NSX 100/160 and EasyPact CVS 100/160. It provides an earth-leakage protection when installed directly on the device terminals. It directly actuates the trip unit in case of insulation fault. The addition of this Vigi add-on module does not modify Compact NSX 100/160 or EasyPact CVS 100/160 characteristics. It is a MH type module in 3 poles version, self-powered by the input voltage. The operational voltage for the Vigi add-on is from 200VAC to 440VAC 50/60Hz. The sensitivity is adjustable from 30mA to 10A, the time delay is also adjustable. The dimensions of the circuit breaker equipped with this module are 105mm x 236mm x 86mm.

    Specifications

    Main

    range of productComPact NSX100...250
    rangeComPact
    product or component typeVigi add-on
    device applicationWiring
    range compatibilityComPact (ComPact NSX100) circuit breaker
    ComPact (ComPact NSX160) circuit breaker
    EasyPact (EasyPact CVS100) circuit breaker
    EasyPact (EasyPact CVS160) circuit breaker
    poles description3P
    [In] rated current160 A
    100 A
    earth-leakage add-on module nameMH
    earth-leakage protection classClass A
    residual earth-leakage sensitity adjustment typeAdjustable 5 settings
    earth-leakage sensitivity0.03 A
    0.3 A
    1 A
    3 A
    10 A
    residual earth-leakage time delay adjustment typeAdjustable 4 settings
    [Δt] residual earth-leakage time delay adjustment0 ms
    150 ms
    310 ms
    60 ms

    Complementary

    network typeAC
    network frequency50/60 Hz
    [Ue] rated operational voltage200...440 V AC 50/60 Hz conforming to IEC 60947-2
    earth-leakage protectionWith
    maximum breaking time800 ms
    overvoltage categoryClass II

    Environment

    electrical shock protection classClass II
    StandardsIEC 60947-2

    Packing Units

    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height13.234 cm
    Package 1 Width14.202 cm
    Package 1 Length16.885 cm
    Package 1 Weight1.093 kg
    Unit Type of Package 2S04
    Number of Units in Package 212
    Package 2 Height30 cm
    Package 2 Width40 cm
    Package 2 Length60 cm
    Package 2 Weight13.656 kg