Schneider PLC Easy Modicon M200_ Controller M200 20I/12O relay Ethernet - 220V AC

Schneider PLC Easy Modicon M200_ Controller M200 20I/12O relay Ethernet - 220V AC

https://www.hsedubai.com/web/image/product.template/108208/image_1920?unique=a6473c7

Industrial Automation / PLC / Compact PLC

1,546.67 AED 1546.67 AED 1,546.67 AED

1,546.67 AED

Not Available For Sale

This combination does not exist.

Terms and Conditions
30-day money-back guarantee
Shipping: usually 2-3 Business Days, once order is placed, actual lead time will be confirmed.

Attachments

This product is Partsof the Modicon M221 range, an offer of programmable logic controllers for hardwired architectures. This logic controller provides 14 discrete inputs and 10 relay ethernet outputs with 10bit input resolution, normally opened relay output. It is a Modicon logic controller with a rated supply voltage of 100V to 240V AC, an output voltage of 5V to 125V DC, 5V to 250V AC and an output current of 2A with sink or source input logic. This product requires minimal installation and offers tremendous versatility. Integrated connections are USB port with mini B USB 2.0 connector, non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface and ethernet with RJ45 connector. It is a Modicon M221 controller with a network frequency of 50/60Hz, 256KB for internal variables RAM, user application and data RAM, a built-in flash memory of 256KB and a SD card memory capacity of 2GB. It is an IP20 rated product. Its dimensions are 110mm (Width) x 70mm (Depth) x 90mm (Height). It weighs 0.395kg. This product is certified by CE, IACS E10, RCM, ABS, LR, DNV-GL, CSA, EAC and CULus. It meets EN/IEC 60664-1, EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. It supports DIN rail mount. Achieve benchmark performance while increasing profitability with the Modicon M221 through intuitive machine programming with SoMachine Basic, ready-to-use applications and function blocks_ [TM221CE24R]


Specifications

Main

Range of productEasy Modicon M200
Product or component typeLogic controller
[Us] rated supply voltage100...240 V AC
Discrete I/O number32
discrete input numberI2...I5: 4 fast input
I0, I1, I6, I7: 4 high speed input
I8...I19: 12 regular input
discrete output number12 relay
Discrete input voltage24 V
Discrete input voltage typeDC
discrete input current7 mA for input
7 mA for fast input
9 mA for high speed input
discrete input logicSink or source (positive/negative) type 1 conforming to EN/IEC 61131-2
discrete output voltage24 V DC
220 V AC
discrete output current2 A for relay output
Discrete output typeRelay normally open
power consumption in VA55…66 VA at 100...240 V AC (with max I/O)
Complementary
maximum number of I/O expansion module4 with 76 discrete output(s) for relay output
Supply voltage limits85…264 V
Network frequency50/60 Hz
Inrush current50 A
voltage state 1 guaranteed>= 15 V for input
voltage state 0 guaranteed<= 5 V for input
input impedance3.3 kOhm for discrete input
response time10 ms turn-on, Q0...Q11 terminal(s) for output
10 ms turn-off, Q0...Q11 terminal(s) for output
5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input
5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input
100 µs turn-off, I2...I5 terminal(s) for fast input
35 µs turn-on, I2...I5 terminal(s) for fast input
100 µs turn-off, I8...I13 terminal(s) for regular input
35 µs turn-on, I8...I13 terminal(s) for regular input
125 µs turn-off, I14...I19 terminal(s) for regular input
55 µs turn-on, I14...I19 terminal(s) for regular input
configurable filtering time0 ms for input
3 ms for input
12 ms for input
output voltage limits30 V DC
250 V AC
maximum current per output common4 A at COM 2
4 A at COM 0
4 A at COM 1
electrical durability100000 cycles AC-12, 240 V, 480 VA, resistive
100000 cycles DC-12, 24 V, 48 W, resistive
switching frequency0.1 Hz with maximum load
mechanical durability20000000 cycles for relay output
minimum load10 mA at 5 V DC for relay output
memory capacity512 byte internal flash for backup of programs
data storage equipment32 GB micro SD card (optional)
battery typeBR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s)
backup time3 years at 25 °C (by interruption of power supply)
execution time for 1 KInstruction0.3 ms for event and periodic task
execution time per instruction0.2 µs Boolean
exct time for event task60 µs response time
clock drift<= 90 s/month at 25 °C
regulation loopAdjustable PID regulator up to 14 simultaneous loops
control signal typeQuadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode)
Pulse/direction at 100 kHz for fast input (HSC mode)
Single phase at 100 kHz for fast input (HSC mode)
CW/CCW at 100 kHz for fast input (HSC mode)
counting input number4 fast input (HSC mode) at 100 kHz 32 bits
integrated connection typeUSB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with terminal block connector and RS485 interface
Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface
Isolated serial link serial 2 with terminal block connector and RS485 interface
transmission rate1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
12 Mbit/s for USB
communication port protocolUSB port: USB - SoMachine-Network
Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
local signalling1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED (green) for SL1
1 LED per channel (green) for I/O state
electrical connectionMini B USB 2.0 connectorfor a programming terminal
removable screw terminal blockfor inputs
removable screw terminal blockfor outputs
removable screw terminal block, 4 terminal(s) for connecting the serial link1
removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply
maximum cable distance between devicesUnshielded cable: <50 m for input
Shielded cable: <10 m for fast input
Shielded cable: <10 m for high speed input
Unshielded cable: <150 m for output
insulationNon-insulated between inputs
Between output and internal logic at 1780 V AC
Between output groups at 1780 V AC
Between supply and internal logic at 1780 V AC
Between input and internal logic at 500 V AC
Between fast input and internal logic at 500 V AC
Between input groups at 500 V AC
sensor power supply24 V DC at 300 mA supplied by the controller
MarkingCE
mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715
Height90 mm
Depth70 mm
Width175 mm
Product weight0.504 kg
Environment
IP degree of protectionIP20 with protective cover in place
StandardsEN/IEC 61131-2
EN/IEC 61010-2-201
electromagnetic compatibilityElectrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m (80 MHz...3 GHz) conforming to EN/IEC 61000-4-3
Magnetic field at power frequency - test level: 30 A/m conforming to EN/IEC 61000-4-8
Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 0.5 kV (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (AC)) conforming to EN/IEC 61000-4-5
Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
shock resistance15 gn for 11 ms
30 gn for 6 ms
Immunity to microbreaks10 ms
vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail
1 gn at 8.4…150 Hz on symmetrical rail
3.5 mm at 5…8.7 Hz on panel mounting
2 gn at 8.7…150 Hz on panel mounting
relative humidity10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
ambient air temperature for operation0…55 °C (horizontal installation)
Ambient air temperature for storage-25…70 °C
Pollution degree<= 2
Operating altitude0...2000 m
Storage altitude0…3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.5 cm
Package 1 Width13.8 cm
Package 1 Length18.5 cm
Package 1 Weight749.0 g
Unit Type of Package 2S03
Number of Units in Package 212
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight9.4 kg
Unit Type of Package 3P06
Number of Units in Package 396
Package 3 Height75.0 cm
Package 3 Width80.0 cm
Package 3 Length60.0 cm
Package 3 Weight83.2 kg