Schneider Sensors Nema_ 9007FT foundry limit switch - standard - spring return - CW+CCW - M20_ [9007FTSB1M11]
Industrial Automation / Sensor / Limit Switch
This product is Partsof the Nema Limit Switches range, an offer of heavy duty metal limit switches. The limit switch is a device that converts a mechanical motion into an electrical control signal. It has 1 normally closed + 1 normally opened, SPDT-DB (single pole double throw, double break) form Z, snap action contacts. The spring return mechanism without operating lever supports a lateral approach and switch actuation from CW and CCW, left or right. It is furnished with screw clamp terminals for electrical connection. It is a safety switch with a conventional enclosed thermal current of 20A. It is an IP67 and NEMA 1/2/4/12/13 rated product. This NEMA limit switch has fixed body made of metal. Its dimensions are 57.15mm (width) x 86.61mm (depth) x 118.36mm (height) and weighs 1.13kg. It is suitable for use in mill and foundry, iron and steel, cement and glass applications. It is also used in material handling, conveyance, carousels and automatic storage/retrieval applications. This product is certified by UL and CSA. It complies with UL 508, NEMA A600, IEC 609470-1 and C22-2-14 standards. Foundry switch is suitable for severe duty applications, convertible sequences and 59mm housing. Extended operating and reset forces and heavy-duty contacts that will break 20A AC/DC. Compliant with US and international standards, the 9007 series limit switches can withstand the impact of heavy industry. This constitutes a comprehensive range of limit switches rigged and dependable built with unparalleled quality._ [9007FTSB1M11]
Specifications
Main
Range of product | 9007 |
---|---|
Series name | Severe duty foundry |
Product or component type | Limit switch |
Device application | Standard foundry switch |
Device short name | 9007T/FT |
Body type | Fixed |
Head type | Rotary head |
Sale per indivisible quantity | 1 |
Complementary
Base plate style | Style B |
---|---|
Body material | Cast zinc |
Fixing mode | By the body |
Movement of operating head | Rotary |
Type of operator | Spring return without operating lever |
Contact sequence number | 1 |
Function available | - |
Switch actuation | From left or right CW and CCW |
Type of approach | Lateral approach |
electrical connection | Screw-clamp terminals AWG 22...AWG 12 |
cable entry | 1 entry for M20 - 20 mm conforming to BS 4568 |
Number of poles | 1 |
Switch function | SPDT-DB |
Contact form | Form Z |
Contact operation | Snap action |
Contacts usage | - |
Contacts material | Silver flashed copper |
Positive opening | Without |
Minimum torque for tripping | 1.13 N.m |
maximum actuation speed | 130 ft/min with 30° cam angle, levers only 90 ft/min with 45° cam angle, levers only |
tripping angle | 14 ° |
Maximum displacement angle | 89 ° |
repeat accuracy | +/- 0.004 in linear travel of cam on 1.5 in lever arm |
contact code designation | A600, AC (Ue = 600 V) Ie = 5 A conforming to NEMA rating designation A600, AC (Ue = 480 V) Ie = 6.25 A conforming to NEMA rating designation A600, AC (Ue = 240 V) Ie = 12.5 A conforming to NEMA rating designation A600, AC (Ue = 120 V) Ie = 20 A conforming to NEMA rating designation P600, DC (Ue = 600 V) Ie = 0.2 A conforming to NEMA rating designation P600, DC (Ue = 250 V) Ie = 1 A conforming to NEMA rating designation P600, DC (Ue = 120 V) Ie = 5 A conforming to NEMA rating designation |
[Ithe] conventional enclosed thermal current | 20 A |
[Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to IEC 609470-1 600 V (pollution degree 3) conforming to UL 508 600 V (pollution degree 3) conforming to CSA C22.2 No 14 |
[Uimp] rated impulse withstand voltage | 2.5 kV AC for 1 minute conforming to CE 2.2 kV AC for 1 minute conforming to UL 2.64 kV AC for 1 minute conforming to CSA |
short-circuit protection | 20 A Bussmann class CC KTK-R-21 fuse, type non-time delay |
Width | 57.15 mm |
Height | 118.36 mm |
Depth | 86.61 mm |
Net weight | 1.13 kg |
Terminals description ISO n°1 | B (right side contact) A (left side contact) |
Environment
shock resistance | 30 gn for 9 ms conforming to IEC 60068-2-27 |
---|---|
vibration resistance | 10 gn (f= 10…55 Hz) conforming to IEC 60068-2-6 |
NEMA degree of protection | NEMA 1 conforming to Nema type 250 NEMA 2 conforming to Nema type 250 NEMA 4 conforming to Nema type 250 NEMA 12 conforming to Nema type 250 NEMA 13 conforming to Nema type 250 |
IP degree of protection | IP67 conforming to IEC 60529 |
electrical shock protection class | Class 0 conforming to IEC 61140 |
Ambient air temperature for operation | -23…85 °C |
Ambient air temperature for storage | -23…85 °C |
Protective treatment | Corrosion resistant gray paint |