Schneider Sensors OsiSense XC_ limit switch XCKJ - steel roller lever variable length - 1NC+1NO - snap - 1/2NPT_ [XCKJ10543H7]
Industrial Automation / Sensor / Limit Switch
This product is part of the XC Standard limit switch range. The limit switch is a device that converts a mechanical motion into an electrical control signal. It is intended for all industrial machine applications such as packaging, materials handling, conveying, machining, food and beverage, service sector. It has one normally closed and one normally open, snap action contacts without positive opening operation and provides switch actuation by 30 degree cam. It has a rated operational current of 3A at 240VAC (A300) (AC-15), 0.27A at 250VDC (Q300) (DC13). Its mechanical durability is 30 million operating cycles and electrical durability is 5 million operating cycles. It has a variable length spring return metal roller lever and supports lateral approach in one or two programmable directions. The movement of the operating head is rotary. It is furnished with screw clamp terminals for electrical connection. Limit switch has one entry tapped for 1/2in NPT cable gland. It is compliant with UL, CSA, CCC, and EN/IEC standards and is IP66 rated. Limit switches for contact sensing of inflexible objects. An offer of positive opening snap action contacts for a simpler and safer machine design. IEC standard format limit switches consist of products designed according to EN 50047, EN 50041 as well as popular XCM and XCKM limit switches ranges.
Specifications
Main
Range of product | Telemecanique Limit switches XC Standard |
---|---|
Series name | Standard format |
Product or component type | Limit switch |
Device short name | XCKJ |
sensor design | - |
Body type | Fixed |
Head type | Rotary head |
Material | Metal |
Body material | Zamak |
Head material | Zamak |
Fixing mode | By the body |
Movement of operating head | Rotary |
type of operator | Spring return roller lever metal variable length |
type of approach | Lateral approach, 1 or 2 programmable direction |
cable entry | 1 entry tapped for 1/2" NPT cable gland |
Number of poles | 2 |
Contacts type and composition | 1 NC + 1 NO |
Contact operation | Snap action |
Complementary
Switch actuation | By 30° cam |
---|---|
electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² |
Contacts insulation form | Zb |
Number of steps | 1 |
Positive opening | Without |
Minimum torque for tripping | 0.25 N.m |
maximum actuation speed | 1.5 m/s |
[Ie] rated operational current | 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A |
[Ithe] conventional enclosed thermal current | 10 A |
[Ui] rated insulation voltage | 300 V conforming to UL 508 500 V (pollution degree 3) conforming to IEC 60947-1 300 V conforming to CSA C22.2 No 14 |
maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60664 6 kV conforming to IEC 60947-1 |
short-circuit protection | 10 A cartridge fuse, type gG |
electrical durability | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
Mechanical durability | 30000000 cycles |
Width | 40 mm |
Height | 77 mm |
Depth | 44 mm |
Net weight | 0.485 kg |
Terminals description ISO n°1 | (21-22)NC (13-14)NO |
Environment
shock resistance | 50 gn for 11 ms conforming to IEC 60068-2-27 |
---|---|
vibration resistance | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
IP degree of protection | IP66 conforming to IEC 60529 |
IK degree of protection | IK07 conforming to EN 50102 |
overvoltage category | Class I conforming to IEC 61140 Class I conforming to NF C 20-030 |
Ambient air temperature for operation | -25…70 °C |
Ambient air temperature for storage | -40…70 °C |
Protective treatment | TH |
Product certifications | CSA UL CCC |
Standards | IEC 60947-5-1 IEC 60204-1 CSA C22.2 No 14 CENELEC EN 50041 EN 60947-5-1 UL 508 EN 60204-1 |