Schneider Power Supply Phaseo ABL7, ABL8_ Regulated Power Supply, 100-240V AC, 24V 2.1 A, single phase, Optimized_ [ABLS1A24021]

Schneider Power Supply Phaseo ABL7, ABL8_ Regulated Power Supply, 100-240V AC, 24V 2.1 A, single phase, Optimized_ [ABLS1A24021]

https://www.hsedubai.com/web/image/product.template/49611/image_1920?unique=15f46e8

Industrial Automation / Power Supply / Regulator

323.00 AED 323.0 AED 323.00 AED

323.00 AED

Not Available For Sale

This combination does not exist.

Terms and Conditions
30-day money-back guarantee
Shipping: usually 2-3 Business Days, once order is placed, actual lead time will be confirmed.

Attachments

This ABLS regulated switch mode power supply (SMPS) supplies direct current voltage. It has a rated input of 100V to 240V AC, a rated output current of 2,1A at 24V DC and a rated power output of 50W. It is ideal for supplying DC voltage necessary for automation equipment designed for applications in industrial, commercial and residential applications such as conveying, packaging, control, food & beverage, mining, oil & gas and water. It installs on omega rail or fixing by screw. Its width is 30mm, its height is 75mm, its depth is 89,5mm. It ensures a protection against overloads and short-circuits with automatic restart after the source of overload/short-circuit has been corrected. It weighs 0.180kg. It is a power supply for industrial use, rail mounting. It conforms to EN62368-1, ENIEC61010-1/2-201, ENIEC61204-3, EN61000-6-1/2/3/4, EN61000-3-2-3, UL62368-1, UL61010-2-201/-1-201, CSAC22.2No62368-1/No61010-2-201/No61010-1 standards, and certified by CE, CUL listed/recognized, RCM, CBscheme. The Acti9 iC60 range of Miniature Circuit Breakers is recommanded for its protection. The type of protection is 6A, C curve or 10A, B-curve. It has in the front face a LED indicating presence of DC output voltage, and a QR code for access to the latest technical documentation. Thanks to its compact housing, it can be installed either in enclosures or industrial panels by clipping on omega (DIN) rail. It brings energy to your automated systems. Designed for simple machines and applications, modular power supplies are primarily appreciated for their extreme compactness._ [ABLS1A24021]

Specifications

Main

Range of productModicon Power Supply
Product or component typePower supply
Power supply typeRegulated switch mode
Variant optionOptimized
Enclosure materialPlastic
Nominal input voltage100...240 V AC single phase
100...240 V AC 2 phases
Rated power in W50 W
output voltage24 V DC
Power supply output current2.1 A

Complementary

Input voltage limits85...264 V AC
Nominal network frequency50…60 Hz
Network system compatibilityTN
TT
IT
maximum leakage current1 mA 240 V AC
input protection typeIntegrated fuse (not interchangeable) 3.15 A
External protection (recommended) 20 A Curve C
External protection (recommended) 10 A Curve B
External protection (recommended) 6 A Curve C
inrush current35.0 A at 115 V
75.0 A at 230 V
power factor0.45 at 115 V AC
0.35 at 230 V AC
efficiency86 % at 115 V AC
88 % at 230 V AC
Output voltage adjustment24...28 V
Power dissipation in W7.5 W
current consumption< 1.1 A 115 V AC
< 0.65 A 230 V AC
Turn-on time< 3 s
holding time> 20 ms 100 V AC
> 100 ms 230 V AC
Startup with capacitive loads3000 µF
Residual ripple< 75 mV
Expected capacitor life time10 year(s)
meantime between failure [MTBF]2000000 h at 25 °C, full load conforming to SR 332
900000 h at 55 °C, 80 % load conforming to SR 332
output protection typeAgainst overload and short-circuits, protection technology: automatic reset
Against over temperature, protection technology: manual reset
Against overvoltage, protection technology: manual reset
connections - terminalsScrew connection: 0.5...2.5 mm², (AWG 20...AWG 14) for input/output
line and load regulation< 0.5 % network 0 to 100 % load at 25 °C
< 1 % network full voltage range in line at 25 °C
status LED1 LED (green) output voltage
Depth89.5 mm
Height75 mm
Width30 mm
Net weight0.180 kg
Output couplingParallel
Serial
mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Double-profile DIN rail
supplySELV conforming to EN/IEC 60950-1
SELV conforming to EN/IEC 60204-1
SELV conforming to IEC 60364-4-41
dielectric strength3000 V AC with input to output

Environment

StandardsEN 62368-1
EN/IEC 61204-3
EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
EN 61000-3-2
EN 61000-3-3
UL 62368-1
CSA C22.2 No 62368-1
UL 508
CSA C22.2 No 107.1
EN/IEC 62368-1
product certificationsCE
CUL listed
CUL recognized
RCM
CB Scheme
EAC
KC
NEC: class 2
environmental characteristic3M4 conforming to IEC 60721-3-3
operating altitude< 2000 m
shock resistance100 m/s² for 11 ms
IP degree of protectionIP20
Ambient air temperature for operation-20…-10 °C with current derating of 2 % per °C mounting position A < 2000 m
-10…55 °C without derating mounting position A < 2000 m
55…70 °C with current derating of 3.33 % per °C mounting position A < 2000 m
electrical shock protection classClass I
Pollution degree2
vibration resistance3 mm (f= 2…9 Hz) conforming to IEC 60068-2-6
10 m/s² (f= 9…200 Hz) conforming to IEC 60068-2-6
Electromagnetic immunityImmunity to electrostatic discharge - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Immunity to electrostatic discharge - test level: 9 kV (air discharge) conforming to EN/IEC 61000-4-2
Immunity to conducted RF disturbances - test level: 10 V/m (80 MHz...2 GHz) conforming to EN/IEC 61000-4-3
Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to EN/IEC 61000-4-3
Immunity to conducted RF disturbances - test level: 3 V/m (2.7...6 GHz) conforming to EN/IEC 61000-4-3
Immunity to fast transients - test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4
Surge immunity test - test level: 3 kV (between power supply and earth) conforming to EN/IEC 61000-4-5
Surge immunity test - test level: 1.5 kV (between phases) conforming to EN/IEC 61000-4-5
Immunity to conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8
Immunity to voltage dips conforming to EN/IEC 61000-4-11
Disturbing field emission conforming to EN 55016-2-3
Limits for harmonic current emissions conforming to EN 61000-3-2
Conducted disturbance emission conforming to EN 55016-1-2
Conducted disturbance emission conforming to EN 55016-2-1
electromagnetic emissionConducted emissions conforming to EN 61000-6-3
Radiated emissions conforming to EN 61000-6-4