Schneider Breaker EasyPact EZC_ circuit Breaker Easypact EZC100H - TMD - 50 A - 1 pole 1d_ [EZC100H1050]

Schneider Breaker EasyPact EZC_ circuit Breaker Easypact EZC100H - TMD - 50 A - 1 pole 1d_ [EZC100H1050]

https://www.hsedubai.com/web/image/product.template/72799/image_1920?unique=826701f

Electrical / Breaker / MCCB

136.00 AED 136.0 AED 136.00 AED

136.00 AED

Not Available For Sale

This combination does not exist.

Terms and Conditions
30-day money-back guarantee
Shipping: usually 2-3 Business Days, once order is placed, actual lead time will be confirmed.

Attachments

EasyPact EZC100H is a 1 pole fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 25kA rms at 240VAC 50/60Hz. The operational voltage is 415VAC 50/60Hz or 125VDC. The rating of the thermal-magnetic trip unit is 50A. The trip unit provides fixed overload and instantaneous protections. The dimensions for this 1 pole version are 25mm (W) x 130mm (H) x 60mm (D). Easypact EZC100H is compliant with international standards (IEC 60947, UL 508) and marine certifications.


Specifications

Main

range of productEasyPact
product or component typeCircuit breaker
device short nameEasypact EZC100H
circuit breaker nameEasypact EZC100H
device applicationDistribution
poles description1P
protected poles description1t
network typeDC
AC
network frequency50/60 Hz
[In] rated current50 A at 40 °C
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
[Ue] rated operational voltage125 V DC conforming to IEC 60947-2
415 V AC 50/60 Hz conforming to IEC 60947-2
breaking capacity codeH
breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2
25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity5 kA at 125 V DC conforming to IEC 60947-2
12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolationYes conforming to IEC 60947-2
utilisation categoryCategory A
trip unit nameTM-D
trip unit technologyThermal-magnetic
trip unit rating50 A at 50 °C
protection typeOverload protection
Short-circuit protection
pollution degree3 conforming to IEC 60664-1
3 conforming to IEC 947-1

Complementary

control typeToggle
mounting modeFixed
mounting supportBackplate
upside connectionFront
downside connectionFront
mechanical durability8500 cycles
electrical durabilityCategory A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
connection pitch25 mm
local signallingPositive contact indication
neutral protection settingWithout protection
earth-leakage protectionWithout
Height130 mm
width25 mm
Depth60 mm

Environment

StandardsGB/T 14048.2
EN/IEC 60947-1
JIS C8201-2-2
EN/IEC 60947-2
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-35…85 °C

Packing Units

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.0 cm
Package 1 Width3.0 cm
Package 1 Length10.0 cm
Package 1 Weight333.0 g
Unit Type of Package 2S02
Number of Units in Package 232
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.111 kg
Unit Type of Package 3P12
Number of Units in Package 31024
Package 3 Height75 cm
Package 3 Width120 cm
Package 3 Length80 cm
Package 3 Weight377 kg