Schneider PLC Modicon M241_ controller M221 40 IO relay Ethernet_ [TM221CE40R]

Schneider PLC Modicon M241_ controller M221 40 IO relay Ethernet_ [TM221CE40R]

https://www.hsedubai.com/web/image/product.template/43484/image_1920?unique=1f23ac1

Industrial Automation / PLC / Compact PLC

1,596.10 AED 1596.1000000000001 AED 1,596.10 AED

1,596.10 AED

Not Available For Sale

This combination does not exist.

Terms and Conditions
30-day money-back guarantee
Shipping: usually 2-3 Business Days, once order is placed, actual lead time will be confirmed.

Attachments

This product is Partsof the Modicon M221 range, an offer of programmable logic controllers for hardwired architectures. This logic controller provides 24 discrete inputs and 16 relay ethernet outputs with 10bit input resolution, normally opened relay output. It is a Modicon logic controller with a rated supply voltage of 100V to 240V AC, an output voltage of 5V to 125V DC, 5V to 250V AC and an output current of 2A with sink or source input logic. This product requires minimal installation and offers tremendous versatility. Integrated connections are USB port with mini B USB 2.0 connector, non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface and ethernet with RJ45 connector. It is a Modicon M221 controller with a network frequency of 50/60Hz, 256KB for internal variables RAM, user application and data RAM, a built-in flash memory of 256KB and a SD card memory capacity of 2GB. It is an IP20 rated product. Its dimensions are 160mm (Width) x 70mm (Depth) x 90mm (Height). It weighs 0.456kg. This product is certified by CE, IACS E10, RCM, ABS, LR, DNV-GL, CSA, EAC and CULus. It meets EN/IEC 60664-1, EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. It supports DIN rail mount. Achieve benchmark performance while increasing profitability with the Modicon M221 through intuitive machine programming with SoMachine Basic, ready-to-use applications and function blocks_ [TM221CE40R]


Specifications

Main

range of productModicon M221
product or component typeLogic controller
[Us] rated supply voltage100...240 V AC
discrete input number24, discrete input conforming to IEC 61131-2 Type 1
analogue input number2 at 0...10 V
discrete output typeRelay normally open
discrete output number16 relay
discrete output voltage5...125 V DC
5...250 V AC
discrete output current2 A

Complementary

discrete I/O number40
maximum number of I/O expansion module7 for relay output
supply voltage limits85…264 V
network frequency50/60 Hz
inrush current40 A
maximum power consumption in VA70 VA at 100...240 V with max number of I/O expansion module
41 VA at 100...240 V without I/O expansion module
power supply output current0.52 A 5 V for expansion bus
0.24 A 24 V for expansion bus
discrete input logicSink or source (positive/negative)
discrete input voltage24 V
discrete input voltage typeDC
analogue input resolution10 bits
LSB value10 mV
conversion time1 ms per channel + 1 controller cycle time for analogue input analog input
permitted overload on inputs+/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
voltage state 1 guaranteed>= 15 V for input
voltage state 0 guaranteed<= 5 V for input
discrete input current7 mA for discrete input
5 mA for fast input
input impedance3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
response time35 µs turn-off, I2...I5 terminal(s) for input
10 ms turn-on for output
10 ms turn-off for output
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
configurable filtering time0 ms for input
3 ms for input
12 ms for input
output voltage limits125 V DC
277 V AC
maximum current per output common7 A
absolute accuracy error+/- 1 % of full scale for analog input
electrical durability100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, resistive
300000 cycles AC-12, 240 V, 160 VA, resistive
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, resistive
300000 cycles DC-12, 24 V, 16 W, resistive
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
switching frequency20 switching operations/minute with maximum load
mechanical durability20000000 cycles for relay output
minimum load1 mA at 5 V DC for relay output
protection typeWithout protection at 5 A
reset time1 s
memory capacity256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
data backed up256 kB built-in flash memory for backup of application and data
data storage equipment2 GB SD card (optional)
battery typeBR2032 lithium non-rechargeable, battery life: 4 year(s)
backup time1 year at 25 °C (by interruption of power supply)
execution time for 1 KInstruction0.3 ms for event and periodic task
execution time per instruction0.2 µs Boolean
exct time for event task60 µs response time
maximum size of object areas8000 %MW memory words
255 %TM timers
512 %KW constant words
255 %C counters
512 %M memory bits
realtime clockWith
clock drift<= 30 s/month at 25 °C
regulation loopAdjustable PID regulator up to 14 simultaneous loops
counting input number4 fast input (HSC mode) at 100 kHz 32 bits
counter functionSingle phase
A/B
Pulse/direction
integrated connection typeUSB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface
Ethernet with RJ45 connector
supply(Serial)serial link supply: 5 V, <200 mA
transmission rate1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
communication port protocolUSB port: USB - SoMachine-Network
Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
Ethernet
port Ethernet10BASE-T/100BASE-TX 1 port with 100 m copper cable
communication serviceDHCP client
Modbus TCP client
Ethernet/IP adapter
Modbus TCP server
Modbus TCP slave device
local signalling1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED per channel (green) for I/O state
1 LED (green) for SL
Ethernet network activity (green) for ACT
Ethernet network link (yellow) for Link (Link Status)
electrical connectionRemovable screw terminal block for inputs
removable screw terminal block for outputs
terminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
maximum cable distance between devicesShielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
insulationBetween input and internal logic at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Between supply and ground at 1500 V AC
Between sensor power supply and ground at 500 V AC
Between input and ground at 500 V AC
Between output and ground at 1500 V AC
Between supply and internal logic at 2300 V AC
Between sensor power supply and internal logic at 500 V AC
Between output and internal logic at 2300 V AC
Between Ethernet terminal and internal logic at 500 V AC
Between supply and sensor power supply at 2300 V AC
MarkingCE
sensor power supply24 V DC at 250 mA supplied by the controller
mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Height90 mm
Depth70 mm
width160 mm
Net weight0.456 kg

Environment

StandardsEN/IEC 60664-1
EN/IEC 61131-2
EN/IEC 61010-2-201
product certificationsDNV-GL
EAC
ABS
cULus
LR
RCM
CSA
IACS E10
environmental characteristicOrdinary and hazardous location
resistance to electrostatic discharge8 kV in air conforming to EN/IEC 61000-4-2
4 kV on contact conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2...2.7 GHz conforming to EN/IEC 61000-4-3
resistance to magnetic fields30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
resistance to fast transients2 kV (power lines) conforming to EN/IEC 61000-4-4
2 kV (relay output) conforming to EN/IEC 61000-4-4
1 kV (I/O) conforming to EN/IEC 61000-4-4
1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
1 kV (serial link) conforming to EN/IEC 61000-4-4
surge withstand2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5
2 kV relay output common mode conforming to EN/IEC 61000-4-5
1 kV I/O common mode conforming to EN/IEC 61000-4-5
1 kV shielded cable common mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5
1 kV relay output differential mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
resistance to conducted disturbances10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6
3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emissionConducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to EN/IEC 55011
Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to EN/IEC 55011
Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011
Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011
Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011
Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011
Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to EN/IEC 55011
immunity to microbreaks10 ms
ambient air temperature for operation-10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
Ambient air temperature for storage-25…70 °C
relative humidity10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protectionIP20 with protective cover in place
pollution degree<= 2
Operating altitude0...2000 m
Storage altitude0…3000 m
vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
1 gn at 8.4…150 Hz on symmetrical rail
1 gn at 8.4…150 Hz on panel mounting
shock resistance98 m/s² for 11 ms

Packing Units

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.09 cm
Package 1 Width14.183 cm
Package 1 Length21.085 cm
Package 1 Weight830.0 g
Unit Type of Package 2CAR
Number of Units in Package 212
Package 2 Height29.2 cm
Package 2 Width39.8 cm
Package 2 Length57.9 cm
Package 2 Weight11.04 kg